Concrete anchorages - reinforcing bar applications
Products listed in the following table are approved for use on MnDOT projects unless otherwise indicated. Products prohibited from use in sustained tension applications may be used for applications which are not considered to carry sustained tension loads. Adhesives permitted for use with sustained tension applications may be used for all applications (sustained or non-sustained tension). All bar types and hole types marked with "approved" below are approved for use under the conditions stated in the table. Products produced by a manufacturer of a current approved product which are the same formulation, may be used on MnDOT project with certification from the manufacturer that the product has the same formulation and performance as the approved product. All anchorages must be field tested as required by the contract regardless of nominal pullout requirements. Refer to project specifications and plans to determine if the anchors are in sustained tension.
Permitted sustained tension applications are specified in MnDOT Technical Memorandum 24-03-B-01.
Those who use any of these products are responsible to handle, store, use, and dispose of excess material in accordance with all manufacturer’s and Safety Data Sheet (SDS) recommendations.
For use in sustained tension applications
Product | Manufacturer | Approval expiration | Rebar Designations | Hole type: Hammer-drilled | Hole type: Core-drilled |
---|---|---|---|---|---|
A7+ | ITW CCNA | 6/25/2026 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
AC200+ | DEWALT | 7/9/2027 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
RE 500v3 | Hilti | 06/25/2026 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
Red Head C6+ | ITW Red Head | 2/14/2027 | Approved for Rebar Designations #4 through #10 | Approved | Approved |
ULTRABOND HYB-2CC | Adhesive Technology Corp | 2/14/2027 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
Pure 50+ | DEWALT | 7/9/2027 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
Pure 110+ | DEWALT | 7/9/2027 | Approved for Rebar Designations #4 through #10 | Approved | Not approved |
Hilti HIT-HY 100 | Hilti | 7/27/2026 | Approved for Rebar Designations #4 through #10 | Approved | Not approved | Hilti HIT-HY 200 V3 | Hilti | 7/27/2026 | Approved for Rebar Designations #4 through #10 | Approved | Approved | Simpson Strong-Tie AT-3G | Simpson | 09/22/2026 | Approved for Rebar Designations #4 through #10 | Approved | Not Approved |
Ultrabond HS-1CC | ATC | 10/2/2026 | Approved for Rebar Designation #4; not approved for rebar designations #5 through #10 | Approved | Not approved |
ACR-28 Sure-Set | Aerosmith Fastening Systems | 9/15/2025 | Approved for #4 through #6; not approved for #7 through #10 | Approved | Not approved |
CIC1200-A | Aerosmith Fastening Systems | 9/9/2026 | Approved for #4 through #6; not approved for #7 through #10 | Approved | Not approved |
Prohibited from use in sustained tension applications
Product | Manufacturer | Approval expiration | Rebar Designations | Hole type: Hammer-drilled | Hole type: Core-drilled |
---|---|---|---|---|---|
AC100+ Gold | DEWALT | 7/9/2027 | Approved for Rebar Designations #4 through #9 | Approved | Not approved |